> Product IntroductionOur 320W EB with 320W MH lamp has been tested by China and the United States National Laboratory (LBL), their results show its luminous efficacy is 120-130 LMW(lumen per Watt) which exceeds conventional MB 400W MHs luminous efficacy. Therefore it can be used to replace MB 400W MH and achieve high energy-saving. > Type: AR/EB HPS/MH 320W Power: 320W
Characteristic of Input | Characteristic of Output | ||
Rated Voltage (V) | 110V240V | Harmonic Distortion | <10% |
Input current (A) | 1.423.04A | Crest Factor | <1.50 |
Frequency (Hz) | 50/60HZ | Frequency (Hz) | 25100KHZ |
Power Factor | >0.99 | Loss of Input Watts (%) | <10% |
Energy Saving | 30% |
AR/EB 320W for metal halide lamp is named King of Energy-Saving.Compare luminous efficacy between AR/EB 320W MH and MB 400W MH:
Ballast result | AR/EB 320W MH+320W MH lamp | 400W MB+400W standard MH Lamp | 400W MB+High luminousMH lamp | Result |
Luminous efficacy | 120 lm/w | 70 lm/w | 95 lm/w | Luminous flux:AR/EB320W + 320W MH lamp exceed 400W MB + 400W MH lamp |
Luminous flux | 38,400 lm | 28,000 lm | 38,000 lm |
Notethe luminous efficacy of AR/EB 320W MH is 130 lmw60Hztesting by US Light Source Institution. Testing conditions: Outdoor, factory, building and business lighting with MB and AR/EBComparison of Performance and Energy Consumption (Consumption RMB 0.60/kWh) We test a group of MH lamps (100pcs) with 400W MH + 400W MB (with capacitance) systems. Then we tested the MH lamps with 320W MH + AR/EB 320W,The lamps are on 12 hours per day.Results are as follows:
Ballast Type | Consumption) | Consumption/Yr | Charge/Yr. | Charge/Pcs | Luminous |
400W MBWithcapacitance | 0.453×100 | 198,414 | 119,048.40 | 1,190.48 | 34400 |
AR/EB 320W | 0.317×100 | 138,846 | 83,307.60 | 833.08 | 38720 |
Results | Save 30.02% | Save 30.02% | Save 35,740.80 | Save 357.41 | |
*According to this table,if we use AR/EB, we can save RMB 35,740.80 per year; and total luminous flux increases by 12%. |
Report of Comparison by Testing:
Type | 400W MB(with capacitance)+400W MH Lamp | 320W AR/EB+320W MH Lamp |
Energy Usage kwh | 32.62 | 22.82 |
CurrentA | 2.216 | 1.583 |
VoltageV | 219 | 225 |
Harmonic distortion | 29.1% | 4.6% |
Power Factor | 0.864 | 0.998 |
Lumens output (lux.) | 432 | 478 |
Energy saving | 30.02% |